Configuration Commands

Rev 3.0B Feb.08

132

Figure 1-15: AceManager : Telemetry

IPL=n

IP List Dial allows access the Modbus IP list using the first two 
digits of the dial string. 

Example: ATDT1234567 would go to ID “12” on the Modbus 
list and use the associated IP as the destination. 

n=0 : Disabled

n=1 : Enabled

MVLEN=n

Modbus Variant ID Length: Length of the RTU ID in a 
modbus‐variant protocol, in bytes. 

n=1 : This parameter is used to define the length of the 
RTU ID in Modbus‐like protocol data packets. 

n=2 : This parameter is used when the when the MD is set 
to hex 63. 

MVMSK=hh

Modbus Variant ID Mask: Byte hex mask to use when 
extracting the ID. Specify which bits in the ID field to use. This 
parameter is used when the when the Mode Default (MD) is 
set to hex 63. 

hh=hex value 

·

00 ‐ no mask, all 8 bits (default) 

·

0F ‐ only the low order 4 bits 

MVOFF=n

Modbus (variable mode) Offset: Indicates the offset in the data 
of where the Modbus ID starts. 

n=0 ‐ 255