beautypg.com

Safety data sheet océ tds400 printer and scanner – IBM Oce TDS400 User Manual

Page 226

background image

226

Océ TDS400 User Manual

Safety data sheet Océ TDS400 printer and scanner

The content of this safety data sheet is subject to the disclaimer of liability on page 224 of this manual.

PRODUCT SAFETY DATA SHEET

Océ-USA, Inc.

Number

E-718-a-US

Date

August 2000

Copyright © 2000 Océ-Technologies B.V., Venlo, NL

Model

Océ TDS400

Description

Multifunction device, instant copying/printing, consisting of an electrophotographic printer,
console model, plain paper, organic photoconductive drum, powder toner and a free standing
scanner.

Max. process speed

3 m/min

Dimensions

Width

Engine

Scanner

Controller

Monitor (17”)

1352 mm

1240 mm

206 mm

299 mm

Depth

899 mm

615 mm

437 mm

410 mm

Height

1251 mm

1105 mm

444 mm

409 mm

Weight

175 kg

65 kg

15 kg

15 kg

10 kg (extra roll)

Voltage

100/115/230 V

100/115/230 V

100/230 V

100-230 V

Frequency

50/60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

Current-rated

15/15/7,5 A

1,1/1,1/0,7 A

0,9 A

Current-max

20/20/10 A

1,6/1,6/0,8 A

6/3 A

1,4 A

Power consumption, stand by

30 W

27

W

Power consumption, operation

1,5 kW

1

40 W

40 W

70 W

EPA

ENERGY STAR

®

* Power consumption

sleep mode

52 W (total system)

Mains connection

Cables with plug

Safety class

I

(IEC 536) Protective earth connection

Protection class

IP 20

(IEC 529)

Sound pressure level
(at bystander position)

Standby

In operation

24 dB(A)

main body 54 dB(A)
impulse

L

i

= 4 dB(A)

Sound power level

41 dB(A)

main body 63 dB(A)

Radio interference

Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.

Radiation

Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)

Heat emission

Standby 182 W; at continuous operation 1,8 kW

Ozone emission

0,04 mg/min at continuous operation

Room volume

Recommendation: min. 25 m

3

Room ventilation

Recommendation: min.12,5 m

3

/h (natural ventilation)

Use simulation at random
operation

With a room volume and ventilation as recommended and a daily volume of 150 m (much
more than average) the use simulation at random operation gives the following ozone
concentrations:
- Time weighted average

0,01 mg/m

3

(0,005 ppm)

- Peak

0,002 mg/m

3

(0,001 ppm)

Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone

0,2 mg/m

3

(0,1 ppm)

Odour Perception Limit for ozone

0,04 mg/m

3

(0,02 ppm)

Consumables

Océ OPC Drum (Océ Safety Data Sheet E-218)
Océ B5 Toner (Océ Safety Data Sheet E-199)
Océ D5 Developer (Océ Safety Data Sheet E-200)
Océ Copying Materials.
This apparatus is suitable for processing recycling paper which complies with the
requirements of ENV 12281.

Additional safety information

The ozone filter does not have to be replaced to keep the ozone concentration in the
workplace below 0,04 mg/m

3

(i.e. the life of the filter equals that of the apparatus).

Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950

EPA

ENERGY STAR

®

LISTED 927F

INFORMATION
TECHNOLOGY
EQUIPMENT

E 69871