Numeric Error Codes

Symptom or Error

FRUs of the SelectaDock
Sequence of Actions

10X, 11X

101: Interrupt failure.

102: Timer failure.

103: Timer interrupt
failure.

104: Protected mode
failure.

105: Last 8042
command not
accepted.
107: NMI test failure.
108: Timer bus test
failure.

109: Low meg-chip
select test.

1. Adapter in slot (if

used).

2. Riser card.

3. Main card.

195
(The computer was docked
to the SelectaDock Docking
System while in hibernation
mode.)

1. Do the following

steps:

a. Turn off and

undock the
system.

b. Turn on and

shut down the
system.

c. Turn off and

dock the system.

1XX

See the hardware
maintenance manual for
the computer. If the
problem persists, go to
“Undetermined Problems”
on page 653.

2XX

201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.

205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.

1. See the hardware

maintenance manual
for the computer
.

2. Main card.

3XX

See “External Keyboard”
on page 629.

SelectaDock III (3547-003)

641