Symptom / Error

FRU / Action in Sequence

2XX

201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.

205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.

1. Go to “Memory

Checkout” on
page 128.

2. DIMM card
3. System board

301, 303, 304, 305, 3XX
(301: Keyboard error.)

1. Go to “Keyboard or

Auxiliary Input
Device Checkout” on
page 129.

2. Keyboard
3. External numeric

keypad

4. External keyboard
5. Keyboard/mouse cable
6. System board

601, 6XX
(601: Diskette drive or
controller error.)

1. Go to “Diskette Drive

Checkout” on
page 130.

2. Diskette drive

assembly

3. Diskette
4. System board

602
(Diskette read error.)

1. Go to “Diskette Drive

Checkout” on
page 130.

2. Diskette
3. Diskette drive

assembly

604
(Unacceptable ID was read
from the diskette drive.)

1. Go to “Diskette Drive

Checkout” on
page 130.

2. Diskette drive

assembly

3. System board

11XX
1101: Serial_A test failure.

1. Serial device

2. Communication cable
3. System board

12XX
1201: Serial_B test failure.

1. System board

(infrared)

17XX

1701: Hard disk
controller failure.

1780, 1790: Hard disk
0 error.

1781, 1791: Hard disk
1 error.

1. Hard disk drive

2. System board