beautypg.com

Infrared-related symptoms, Other symptoms, Intermittent problems – IBM THINKPAD S05L-1270-01 User Manual

Page 160

background image

Infrared-Related Symptoms

Symptom / Error

FRU / Action in Sequence

Unable to communicate
using the Infrared (IR) Port.

1. Make sure the setup

for the IR is correct.

2. Make sure there are

no fluorescent lights
near the computer.
The computer may
receive optical noise
from the fluorescent
light.

3. Run the advanced

diagnostic test. If an
error occurs and a
FRU code is displayed,
replace the parts
shown by the FRU
code.

Other Symptoms

Note: If you cannot find a symptom or error in this list

and the problem remains, see “Undetermined
Problems” on page 149.

Symptom / Error

FRU / Action in Sequence

Errors occur only when the
port replicator is used.

See “Port Replicator
Checkout” on page 134.

PCMCIA slot pin is
damaged.

PCMCIA slots assembly

Intermittent Problems

Intermittent system hang problems can be caused by a
variety of reasons that have nothing to do with a hardware
defect, such as: cosmic radiation, electrostatic discharge,
or software errors. FRU replacement should be
considered only when a recurring problem exists.

When analyzing the intermittent problem, do the following:

1. Run the advanced diagnostic test for the system

board in loop mode at least 10 times.

2. If no error is detected, do not replace any FRUs.
3. If any error is detected, replace the FRU shown by

the FRU code. Rerun the test to verify that no more
errors exist.

148

IBM Mobile Systems HMM