Setting the temperature system, Displaying the power system statistics – Motorola CAJUN P880 User Manual
Page 80
2 - 46
Cajun P880 Routing Switch Installation Guide
2
Setting the Temperature System
You can set the upper and lower temperature warning systems for
your switch’s backplane and slot 1.
To configure the temperature warning systems:
1. In the System Information section of the Web Agent window,
click
Temperature. The Temperature System dialog box opens.
2. Enter the desired temperature warnings for the switch
backplane and slot 1 sensors, and enter the desired
temperature
warning for the CPU sensor.
3. Click on APPLY to save your changes, or Defaults to restore the
temperature defaults.
* Note: The supervisor modules shut down the switching
modules if the temperature reaches the Shutdown
temperature. The modules are restarted if the
temperature goes below the Upper Warning
Temperature. The default Shutdown temperature for the
slot 1 sensor and backplane sensor is 50° C. You can set
the warning temperature to a value lower than 50° C to
ensure prompt notification of an over-temperature
situation.
Displaying the Power System Statistics
To display the power system statistics:
1. In the System Information section of the Web Agent window,
click
Power System. The Power System dialog box opens.
2. Use Table26 to review your power system statistics:
Table 26. Power System Statistical Parameters
Parameter
Definition
Power Supply
Indicates the power supply is present.
Status
Identifies if the power supply is working properly.
Type
Describes the type of power supply detected.