background image

Cajun P880 Routing Switch Installation Guide

1 - 15

Table 2. Cable Pinouts

Recommended Cable
Distances

* Note: The following guidelines are based on IEEE 802.3z Draft

Document, version 3.2.

Table 3. Gigabit Fiber Cable Distances

* The TIA 568 building wiring standard calls for 160/500 MHz*km multimode fiber.
** The international ISO/IEC 11801 building wiring standard calls for 200/500

MHz*km multimode fiber.

*** The ANSI Fibre Channel specification calls for 500/500 MHz*km 50 micron

multimode fiber and 500/500 fiber will be proposed for addition to ISO/IEC 11801.

# Subject to DMD distortion - be sure to use Offset Cabling.

Pinout to 10Base-T Cables

Pinout for RS-232 DB-9
Female Console Port

Pin #

Signal
Description

Pin #

Signal
Description

1

Receive data (+)

1

DCD (output)

2

Receive data (-)

2

TX (output)

3

Transmit data (+) 3

RX (input)

4

Not used

4

DTR (input)

5

Not used

5

SGD (ground)

6

Transmit data (-)

6

DSR (not used)

7

Not used

7

RTS (not used)

8

Not used

8

CTS (output)

N/A

N/A

9

RI (not used)

Standard

Fiber
Type

Diameter
(microns)

Modal
Bandwidth
(MHz*km)

Minimum
Range
(meters)

1000BASE-SX

MM

62.5

160

2 to 220

*

1000BASE-SX

MM

62.5

200

2 to 275

**

1000BASE-SX

MM

50

400

2 to 500

1000BASE-SX

MM

50

500

2 to 550

***

1000BASE-LX

MM

62.5

500

2 to 550

#

1000BASE-LX

MM

50

400

2 to 550

#

1000BASE-LX

MM

50

500

2 to 550

1000BASE-LX

SM

9

NA

2 to 5000

1000BASE-SLX

SM

9

NA

2 to 10000