1 rmi card: cdm-570/570l, -600/600l, -625 – Mocomtech CRS-300 User Manual
Page 31

CRS-300 1:10 Redundancy Switch
Revision 16
Introduction
MN/CRS300.IOM
1–9
CDM-625 Modem
Data Type
TMI Type
RMI Type
EIA-422, V.35
CRS-316
Notes 5, 6
CRS-310
10/100 Ethernet
Note 4
ASI
Notes 5, 6
CRS-325
Notes 5, 6
G.703 Bal (DDI, IDO, DDO, IDI)
Note 2
G.703 Unbal
Note 2
G.703 Bal (DDI, IDO, DDO, IDI)
Note 2
G.703 Unbal (DDI, IDO, DDO, IDI)
Note 2
CRS-330
HSSI
10/100 Ethernet
Note 4
CRS-336
Notes 5, 6
EIA-422, V.35, LVDS
CRS-340
Note 3
G.703 Bal (DDI, IDO, DDO, IDI)
Note 2
G.703 Unbal
Notes 1, 2
Quad E1
CDS-365D
Notes 5, 6
Notes:
1. For CDM-600 modem to switch data (Bal and Unbal) use DB-15 to DB-15
data cable.
2. For CDM-625 modem to switch data (Bal and Unbal) use DB-9 to DB-15
data cable.
3. As of September 2008, the CRS-320 TMI is obsolete. Use the CRS-340
TMI in its place.
4. For CDM-625 where the terrestrial data type is Ethernet, the User can use
only one of any four Ethernet ports on the CDM-625 rear panel in Ethernet
Bridge Mode.
5. From Redundant Modem to RMI, use DB-25 to DB-25 Control cable.
6. From Traffic Modem to TMI, use DB-9 to HD-15 Control cable.
1.4.3.1 RMI Card: CDM-570/570L, -600/600L, -625
Figure 1-5.
CRS-310 RMI
(PL/9579-1)
(2X) BNC - Male DB-15 Male
HD-50 Female DB-25 Male