Mocomtech CRS-300 User Manual
Page 173
![background image](/manuals/117313/173/background.png)
CRS-300 1:10 Redundancy Switch
Revision 16
Connector Pinouts
MN/CRS300.IOM
6–5
6.2.2
EIA-232/422/V.35/LVDS – DB-25F Connector (CRS-320/340)
Table 6-5 indicates the pinout for the DB-25F TMI User Data Interface connector
(RS232/422/V.35/LVDS): J1 on the CRS-320 (obsolete), and J2 on the CRS-340.
Table 6-5. EIA-232/422/V.35/LVDS Connector
Pin
Generic Signal Description
Direction
EIA-422/
RS 530
V.35
EIA-
232
Circuit No.
1 Shield
-
Shield
FG
AA 101
2
Transmit Data A
DTE to Modem
SD A
SD A
BA
103
3
Receive Data A
Modem to DTE
RD A
RD A
BB
104
7 Signal
Ground
-
SG
SG
AB 102
8
Receiver Ready A
Modem to DTE
RR A
RLSD *
CF
109
9
Receive Clock B
Modem to DTE
RT B
SCR B
-
115
10
Receiver Ready B
Modem to DTE
RR
B
-
109
11
Transmit Clock B
DTE to Modem
TT B
SCTE B
-
113
12
Internal Transmit Clock B
Modem to DTE
ST B
SCT B
-
114
14
Transmit Data B
DTE to Modem
SD B
SD B
-
103
15
Internal Transmit Clock A
Modem to DTE
ST A
SCT A
DB
114
16
Receive Data B
Modem to DTE
RD B
RD B
-
104
17
Receive Clock A
Modem to DTE
RT A
SCR A
DD
115
23
External Carrier Off
(EIA-232 ‘1' or TTL ‘low’)
DTE to Modem
-
-
-
-
24
Transmit Clock A
DTE to Modem
TT A
SCTE A
DA
113
Notes:
1. Receiver-Ready is an EIA-232-level control signal on a V.35 interface.
2. DO NOT connect signals to pins which are not shown - these pins are reserved for use by the redundancy
system.
3. 'B' signal lines are not used for EIA-232 applications.
4. For X.21 operation, use the EIA-422 pins, but ignore Receive Clock if the modem is DTE, and ignore
Transmit clocks if the modem is DCE.
TMI User Data Interface connector