4 utility: test, 5 utility: relay – Mocomtech CRS-300 User Manual
Page 201
CRS-300 1:10 Redundancy Switch
Revision 16
Front Panel Operation
MN/CRS300.IOM
7–21
7.8.4 UTILITY: TEST
This is an excellent method to test the whole system before setting the Switch for automatic mode.
The Switch suspends normal system polling and initiates a test:
CONFIG TESTING……2
TM#: 1 OK
TEST COMPLETE.
CHECK 2.
The total configuration of each activated modem is configured into the Redundant Modem in
sequence. If any configuration is not accepted, a fault will be shown on the display.
Press
[CLR]
to return to the top-level (main) menu.
7.8.5 UTILITY: RELAY
POWER-OFF RELAY LOGIC:
DEFAULT INVERT (ENT)
Because the phrasing of the alarm relay “Normally Open” and “Normally Closed” conditions is
easily misinterpreted, to facilitate customer connection to existing external equipment, the logic
of the external relay condition may be inverted.
Select DEFAULT or INVERT using the ◄ ► arrow keys, then press
[ENT]
.