Mocomtech CRS-300 User Manual
Page 196
![background image](/manuals/117313/196/background.png)
CRS-300 1:10 Redundancy Switch
Revision 16
Front Panel Operation
MN/CRS300.IOM
7–16
The three-letter instruction code is indicated also to assist decoding the following problem
parameters:
► For the CDM-600L modem, the code is the hex value of the position of the problem
parameter within the MGC configuration code.
00
NO ERROR
01
TFQ
Tx Frequency
09
TDR
Tx Data Rate
12
TFT
Tx FEC Type
13
TRS
Tx Reed Solomon type
14
TCR
Tx FEC Code Rate
15 TMD Tx
Modulation
16 TSI Tx
Spectrum
Inversion
17
TSC
Tx Scrambler state
18
TPL
Tx Power Level
1C AUP AUPC
enable
1D APP AUPC
parameters
23
TCK
Tx Clock source
24
TXO
Tx Carrier state
25 TIT Tx
Interface
Type
26 TTC Tx
Ternary
Code
27
TFM
Tx Framing Mode
28
TIP
Tx IF Impedance
29
RFQ
Rx Frequency
31
RDR
Rx Data Rate
3A
RFT
Rx FEC Type
3B
RRS
Rx Reed Solomon type
3C
RCR
Rx FEC Code Rate
3D
RMD
Rx Modulation
3E
RSI
Rx Spectrum Inversion
3F
RDS
Rx DeScrambler state
40
RSW
Rx Sweep Width
42
RCK
Rx Clock source
43
EBA
EbNo Alarm point
47
RBS
Rx Buffer Size
4C
RIT
Rx Interface Type
4D
RTC
Rx Ternary Code
4E
RFM
Rx Framing Mode
4F
RIP
Rx IF Impedance
50
EFM
Unit EDMAC Mode
51
ESA
EDMAC Slave Address
55
TST
Unit Test Mode
56
MSK
Unit Alarm Mask
5C
EFR
External Freq Ref
5D
SSI
Statistics Sampling Interval
5E
RTE
Rx Terrestrial Alarm Enable
5F
TTA
Tx Terrestrial Alarm Mask
60
ODU
ODU comms Enable
61
TBA
Tx Backward Alarms
65
RBA
Rx Backward Alarms
69
TVL
Tx audio Volume
6D
RVL
Rx audio Volume
71
DTY
Drop Type
72
ITY
Insert Type
73
TET
Tx ESC Type - 64k or 2 audio
74
RET
Rx ESC Type - 64k or 2 audio
75
ITD
Invert Tx Data
76
IRD
Invert Rx Data
► For the CDM-570L modem, the code is the decimal number indicating the problem
parameter within its MGC configuration code:
00
NO
ERROR
01 ITF Interface
02
LBO
T1 Line Build-Out
03
FRM
Framing mode
04
TFQ
Tx Frequency
05
TFT
Tx FEC Type
06
TMD
Tx Modulation
07
TCR
Tx FEC Code Rate
08
TDR
Tx Data Rate
09
TSI
Tx Spectrum Invert
10
TSC
Tx Scrambler state
11
TPL
Tx Power Level
12
TCK
Tx Clock
13
TDI
Tx Data Invert
14
TXO
Tx Carrier State
15
AUP
AUPC enable
16
APP
AUPC parameters
17
WUD
Warm-Up Delay
18
RFQ
Rx Frequency
19
RFT
Rx FEC Type
20
RMD
Rx Modulation
21
RCR
Rx FEC Code Rate
22
RDR
Rx Data Rate
23
RSI
Rx Spectrum Invert
24
RDS
Rx DeScrambler state
25
RDI
Rx Data Invert
26
RSW
Rx Sweep Width
27
EBA
Eb/No Alarm point
28
RBS
Rx Buffer Size/enable
29
ERF
External Reference setting
30
EFM
EDMAC Framing mode
31
ESA
EDMAC Slave Address range
32 TST Test
mode
33 MSK Alarm
Masks
34
RTS
Request-To-Send control
35
SSI
Statistics Sample Interval