Motorola GT10 User Manual
Page 99
GT10/GT30
5.2
Entering Configuration Settings with GTWIN
76
This is where communication parameters for the PLC and personal computer (GTWIN)
connected to the GT10 are set.
“Communication Parameters” screen
COM. port (Connected to PLC/External Device)
This is used to specify the communication speed and transmission format when the
GT10 is connected to an external device (PLC).
Clicking on the
button displays a pull–down menu from which the value to be set can
be selected.
·
Baud Rate ––– Select 9600, 19200, 38400, 57600, 76,800 or 115200 bits/s.
·
Data Length ––– Select either “7 bits” or “8 bits”.
·
Stop Bits ––– This is fixed at “1 bit”.
·
Parity Bit ––– Select “None”, “Odd”, or “Even”.
Handle Communication Error
Clicking on the
button displays the “Communication Error Remedy” dialog
box. This is used to specify the processing to be used if a communication error occurs.
“Communication Error Remedy” dialog box
For “Retry” and “Waiting”, click the
button and specify the values in the
“Value Set” dialog box that is dis-
played.
For “Display Error Code”, select “Off”,
“On (Hold)”, or “On (Unhold)” by click-
ing the radio button of the desired val-
ue to turn it on.