beautypg.com

Motorola GT10 User Manual

Page 163

background image

GT10/GT30

9.2

What to Do If Something Unusual Occurs (GT30)

140

Related

Solution

Cause

Problem

Screen is

dim

1) The power voltage may be low.
2) The contrast is set too low.
3) The backlight is off due to the [Back-

light Auto–off] setting in the [Setup] of

the GT30 configuration settings in

GTWIN.

1) Supply 24V DC 0.5 A.
2) Bring up the system menu and adjust

the contrast.

3) Touching any area of the screen lights

that area. If a switch part is set on the

touched area, the area will not light

even if touched. To change the setting,

change the content of the backlight

auto–off settings.

page 21
page 126

page 121

Backlight

goes off too

quickly

The backlight auto–off timer setting is too

short.

Change the backlight auto–off timer set-

ting.

page 121

Date / time

display is

incorrect

1) The GT30 internal clock is incorrect.
2) No battery has been inserted.
3) The battery insulation sheet has not

been removed.

4) The battery has run down.
5) The PLC’s internal calendar timer

used as a reference is incorrect.

1) Bring up the system menu and adjust

the clock.

2) Open the cover on the option compart-

ment and install a battery.

3) Open the cover on the option compart-

ment and remove the battery insula-

tion sheet.

4) Replace the battery.
5) Adjust by rewriting the value in the

PLC’s internal calendar timer.

page 127

page 130

page 130

All PLC

manuals

Hold PLC

Device data

content isn’t

saved

1) No battery has been inserted.
2) The battery insulation sheet has not

been removed.

3) The battery has run down.

1) Open the cover on the option compart-

ment and install a battery.

2) Open the cover on the option compart-

ment and remove the battery insula-

tion sheet.

3) Replace the battery.

page 130

page 130

Touch panel

doesn’t work

1) The switch part size setting does not

match the touch panel grid.

2) Valid conditions have been set for the

switch part, but those conditions have

not been met. (Applies only to custom

parts.)

1) When creating screens with GTWIN,

match grid settings to touch panel and

make them valid, then resize.

2) Check that the device status condi-

tions on the PLC side are valid.

GTWIN HELP

GTWIN HELP

No operating

sounds are

heard when

the touch

panel is

pressed.

1) The [Switch Sounds] setting under

[Options] in the switch part attributes

is set to [Disabled].

2) The [Touch Sounds] setting under

[Setup] in the GT30 configuration set-

tings in GTWIN is set to [Disabled].

1) Change the setting to [Enabled].
2) Change the setting to [Enabled].

GTWIN HELP
page 122

Buzzer

sounds

continuously

Bit F of the first word in the basic com-

munication area bit device is set to ON.

Set the F bit to OFF on the PLC side.

(Do not use the basic communication

area with ladder programs.)

page 124

Backlight

color

changes /

flashes

Bits C and D, of the first word (backlight

flashing setting) in the basic communica-

tion area bit device are set to ON.

Perform correct bit operations on the

PLC side. (Do not use the basic commu-

nication area with ladder programs.)