GT10/GT30

1.4 Internal Wiring Connections for Ports

10

1.4.3

Power Supply Terminals

Maker

Shape

Model

Applicable wiring

Tightening

torque

Round

1.25–MS3 0.25 mm

2

to 1.65 mm

2

0.5 N m

JST Mfg.

Front–opening 1.25–B3A

JST Mfg.

Co., Ltd.

Round

2–MS3

1.04 mm

2 to

2.63 mm

2

Front–opening 2–N3A

Applicable crimp terminals

– The terminal screws are M3 screws. We recommend using crimp terminals for

wiring to terminals.

Open–tip terminals

Round terminals

The tightening torque for terminal base screws should be

between 0.5 and 0.6 N

.

m, or less. Operating at a higher

force could cause damage.

If crimp terminals are not being used, wire with a diameter

of 0.5 mm

2

to 1.25 mm

2

should be used for power cables.

In keeping with the European EMC Directive (EMC Direc-

tive 89/336/EEC), the GT10 conforms to European Stan-

dards (EN50081–2:1993, EN50082–2:1995). As a condi-

tion of compatible, a ferrite core should be installed when

wiring to the terminal base (Seiwa Electric Mfg. Co., Ltd.

E04RC281613 or equivalent).

Ferrite core

+24 V

0 V

F.E.

6.0 mm

max.

6.0 mm

max.

The GT30 conform to European EMC directives (EMC Di-

rective 89/336/EEC) and meet European EMC standards

(EN50081–2, EN6100–6–2). A ferrite core (E04SR211132

by Seiwa Electric Mfg. Co., Ltd. or an equivalent product)

should be installed when wiring connections to the terminal

base, as shown below, in order to meet these requirements.

(D–type

ground)

Ferrite core

Ferrite core

When installing make sure that the connection and power

cables are not stressed, as this could result in broken con-

nections.

When installing make sure that the connection and power

cables are not stressed, as this could result in broken con-

nections.