Switching the system unit on/off
V
CAUTION!
●
Before switching the system unit on using the On/Off button, the
PRIMERGY BX900 S1 system unit must be connected to the power
supply for at least a minute.
●
If you switch on the system unit and the connected monitor only
shows flickering stripes, switch it back off immediately (see
"Troubleshooting and tips" on page 77
●
The On/Off button does not disconnect the device from the mains. To
fully disconnect it from the mains, you must unplug the plugs from the
sockets.
●
Turn the server on when the temperature is in its operating
environment range (10–35°C). For details on the operating
environment, refer to "Safety Precautions". When operating the
device outside of this operating environment, the server may operate
improperly, damage data etc. Furthermore, Fujitsu cannot be held
responsible for any related damage, malfunction, or loss of data,
etc.Be sure to wait for 10 seconds or more after shutdown before
turning the server on.After connecting power cable, press the On/Off
button after it passes for more than 10 seconds.
Switching on the system unit
Ê
Press the On/Off button on the system unit (position 4 in
) for 2 seconds. Depending on the BIOS setting, the individual
server blades will also be switched on. This is done in sequence according
to the numbering of the server blade slots (see
Ê
If necessary, switch on the required server blades
The system unit is switched on and the activated server blades perform a
system test and boot the operating system.
Switching off the system unit
The system unit is up and running (server blades are also switched on).
Ê
To properly shut down all server blades, press the On/Off button on the
front of the system unit (position 4 in
) for 4 seconds. All
server blades will then be shut down.