I
The two connection blades within a fabric must have the same
technology, i.e. either Ethernet or Fibre Channel or Infiniband or SAS.
When filling the slots in fabrics 2, 3 and 4, also make sure the server blades are
fitted with the appropriate mezzanine cards. The following rules apply for fitting
the mezzanine card slots of the server blades:
●
If a 1 Gb Ethernet mezzanine card is installed in slot 1 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in fabric 2 of the
system unit.
●
If a 10 Gb Ethernet mezzanine card or a 10Gb CNA mezzanine card is
installed in slot 1 of a server blade, at least one 10 Gb Ethernet connection
blade must be installed in fabric 2 of the system unit.
●
If an FC mezzanine card is installed in slot 1, at least one FC connection
blade must be installed in fabric 2.
●
If an Infiniband mezzanine card is installed in slot 1, an Infiniband connection
blade must be installed in fabric 2.
I
In this case, only one of two channels of the Infiniband mezzanine
card is used.
●
If a 1 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in fabric 3 or in
fabric 4 of the system unit.
●
If a 10 Gb Ethernet mezzanine card or a 10Gb CNA mezzanine card is
installed in slot 2 of a server blade, at least one 1 Gb Ethernet connection
blade must be installed in fabric 3 of the system unit.
●
If an FC mezzanine card is installed in slot 2, at least one FC connection
blade must be installed in fabric 3.
●
If an Infiniband mezzanine card is installed in slot 2, Infiniband connection
blades should be installed in fabrics 3 and 4.
I
In this case, both channels of the Infiniband mezzanine card are
used.
●
If a SAS mezzanine card is installed in slot 2, at least one SAS connection
blade must be installed in fabric 3.
●
You can install combinations of FC, Ethernet, Infiniband and SAS
mezzanine cards in a server blade. In this case, the mezzanine card slots