beautypg.com

FUJITSU M3099EX/EH User Manual

Page 64

background image

3-36

M3099EX/EH OEM Manual

Control register A#20

Control register B#20

X’00' is set when the power is turned on or when a CLEAR
command is issued for initialization.

b7

b0

A #20
B #20

Read density
(256-step selection) (*1)

X'00': Default (same as for X'80')
X'01': Light

X'FF': Dark

*1: This register is valid if bit 0 control register #19 is 1.