Operation error

This response indicates that the error related to operation
specification program occurs.

Byte 3
TEXT

Detailed error Information I

Byte 1
CNT

X'03'

Byte 2
RPS

X'55'

Detailed information I

Detailed information I gives details on errors in command/response
transmission and reception to and from the host computer.

b7

b0

0

0

The dither pattern or the overlay pattern or

γ

pattern

not registered was specified.

The bit or number of an undefined control register
was spedcified.

An operation was specified for a nonexistent option.

An undefined command was received.

Command sequence error

Read area specification error (*1)

*1: Although standard document size bit on control register 5 is on, (Bit 7 takes

"1" and bit 6 takes "0"), the size specifying bits (bits 0 to 4) are not defined.

Control register contents do not change even if the above errors are