beautypg.com

FUJITSU M3099EX/EH User Manual

Page 59

background image

M3099EX/EH OEM Manual

3-31

INTERFACE
SPECIFICATIONS

Control register A#5

X'00' is set when the power is turned on or when a CLEAR
command is issued for initialization. Default document size depends
on the EEPROM setting.

b7

b0

Standard document size

Picking

0: Not specified
1: Specified

A#5

Not defined

Not defined

0000: A0
0001: A1
0010: A2
0011: A3 (Defined only M3099EX)
0100: A4
0101: A5
0110: Double-letter (Defined only M3099EX)
0111: Letter
1000: B0
1001: B1
1010: B2
1011: B3
1100: B4 (Defined only M3099EX)
1101: B5
1110:
1111: Legal

Specifies a vertical or horizontal direction

0: Portrait
1: Landscape

Document selection

00: Set from the operator panel
01: Depends on setting from the operator

panel or the size detector of the ADF

10: Depends on the value of the standard

document size setting register.

Not defined