1.2.3 Environmental

Table 1–2 lists the environmental requirements for the DS20L system.

Table 1– 2 Environmental Parameters

Parameter

Specification

Temperature

Operating

50 to 95

°

F/10 to 35

°

C

NOTE: Maximum operating temperature at sea level;
reduce by 1.

0

F per 1,000 ft (1.

8

C per 1,000 m) above

sea level.

Non-operating

41 to 122° F/5 to 50° C

Storage (60 days)

-40 to 151° F/-40 to 66° C

Rate of change
(operating)

20° F/hr / 11C° /hr

Relative Humidity

Operating

10% to 90%

Non-operating

10% to 95%

Storage (60 days)

10% to 95%

Operating

82° F/28° C

Maximum Wet Bulb
Temperature

Non-operating

90° F/32° C

Storage (60 days)

115° F/46° C

Heat Dissipation

Typical
configuration:

2 GB memory
1 hard disk
1 CD-ROM
2 PCI option
cards

939 BTU/hr