Hitachi NJI-350B User Manual
Page 146

Chapter 5 Instruction Specifications
5-96
Item number
Application instructions-24
Name
Unit
Ladder format
Condition code
Processing time (
µs)
Remark
R7F4
R7F3
R7F2
R7F1
R7F0
Average Maximum
UNIT (d, s, n)
DER
ERR
SD
V
C
↕
z
z
z
z
Instruction format
Number of steps
Condition
Steps
As per the table
below.
UNIT (d, s, n)
4
Bit
Word
Double word
Usable I/O
X
Y
R,
M
TD, SS,
CU, CT
WX WY
WR,
WM TC DX DY
DR,
DM
C
o
nstant
Other
d
Unity result write
destination I/O
{
{
s
Unity destination head I/O
{
n
Numbers of words to be
united
{ n=0 to 4
Function
• Sets the values in the lower four bits of each of the n (1 to 4) words starting from s to the lower four bits of each word in d.
• If n is 1 to 3, the bits not set in d will be “0.”
• The data stored in s to s + n – 1 will be retained even if UNIT is executed.
• Use this instruction so that s + n - 1 does not exceed the I/O range (WRFFF and WM3FF). If it exceeds the I/O range, DER
is equal to '1' and the lower four bits within the range between s and I/O will be set in d.
s
s+1
s+2
s+3
B1
B2
B3
B4
B4
B3
B2
B1
d
When n is 1 : B2 to B4 of d are 0
When n is 2 : B3 to B4 of d are 0
When n is 3 : B4 of d is 0
When n=4
Upper digits
Lower digits
4 bits
Ignored
Notes
• When n=0, it is not executed.
• When n>5, it is not executed.
UNI
T
(d, s,
n)
Processing time (
µs)
n
Average
Maximum
0
75
–
1
100
–
2
103
–
3
106
–
4
109
–