beautypg.com

HP STORAGEWORKS SSL1016 User Manual

Page 128

background image

Troubleshooting

128

SSL1016 Tape Autoloader Reference Guide

Backup server isn't

capable of sending

data to the drive fast

enough.

For the SDLT and Ultrium

drives, the backup server

needs to have lots of memory,

processing power, a

dedicated SCSI bus and a fast

file system.

Network issues.

Most networks aren't capable

of sending data fast enough

to the SDLT and Ultrium

drives. Therefore multiple

network streams of data must

be used for backups

(concurrency.) Also look for

high network traffic, which

can affect backup/restore

performance.

SCSI issues.

Check termination, and cable

length. Use LVDS SCSI and

don't connect any

Single-Ended devices or

terminators on the same bus

as the autoloader. Ultra 160

is recommended for Ultrium 2

performance.

Backup software isn't

configured optimally.

Make sure that the backup

software is configured for the

best performance. (Block size

at 64 and turn software

compression off).

Data set is impairing

performance.

The following can lower

performance: lots of small

(<64k) files, fragmentation,

and uncompressible data.

Real Time Clock keeps

getting reset/cleared.

The DLT1 and SDLT

autoloader versions

cannot maintain the

clock when power is off.

Since the DLT1 and SDLT

versions can not maintain

power to the clock when

power is off or the autoloader

is reset, it is recommended to

configure these autoloaders to

connect to a time server

instead of manually setting

the clock.

Table 13: Suggested Actions for Operational Problems

Problem

Probable Cause

Suggested Action