2200-PMM Allocation Error during MEBx
Download

Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.

1.

Reboot the computer.

2.

Unplug the power cord, re-seat the
memory modules, and reboot the
computer.

3.

If the memory configuration was
recently changed, unplug the
computer, restore the original memory
configuration, and reboot the
computer.

4.

If the error persists, replace the system
board.

2201-MEBx Module did not checksum
correctly

Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.

1.

Reboot the computer.

2.

Unplug the power cord, re-seat the
memory modules, and reboot the
computer.

3.

If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.

4.

If the error persists, replace the system
board.

2202-PMM Deallocation Error during MEBx
cleanup

Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.

1.

Reboot the computer.

2.

Unplug the power cord, re-seat the
memory modules, and reboot the
computer.

3.

If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.

4.

If the error persists, replace the system
board.

2203-Setup error during MEBx execution

MEBx selection or exit resulted in a setup
failure.

1.

Reboot the computer.

2.

Unplug the power cord, re-seat the
memory modules, and reboot the
computer.

3.

If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.

4.

If the error persists, replace the system
board.

Table C-1

Numeric Codes and Text Messages (continued)

194 Appendix C POST Error Messages