L100 Inverter

Confi

gur

in

g

Dr
iv

e P

a

ra

mete

rs

3–33

Analog Summary Table - this table shows all three functions for the analog output FM
(frequency meter) terminal at a glance. Detailed descriptions, related parameters and
settings, and example wiring diagrams are in Chapter 4, starting on page 4–24.

05

AL

Alarm signal

ON

when an alarm signal has occurred and has not
been cleared

OFF

when no alarm has occurred since the last
clearing of alarm(s)

Output Function Summary Table

Option

Code

Terminal

Symbol

Function Name

Description

Analog Function Summary Table

Option

Code

Terminal

Symbol

Function Name

Description

00

A-F

Analog frequency
monitor

PWM (pulse-width-modulated) voltage output which has
a duty cycle proportional to the inverter output frequency

01

A

Analog current
output monitor

PWM (pulse-width-modulated) voltage output which has
a duty cycle proportional to the inverter output current to
the motor. It reaches 100% duty cycle when the output
reaches 200% of the rated inverter current.

02

D

Digital frequency
output monitor

FM (frequency-modulated) voltage output with a constant
50% duty cycle. Its frequency = inverter output frequency.

Technologies Inc.