“C” Group: Intelligent Terminal Functions

Conf

igur

in

g

Dr

iv

e P

a

ra

m

e

ter

s

3–32

The output logic convention is programmable for terminals 11 and 12. The open-collec-
tor output terminals 11 and 12 default to normally open (active low), but you can select
normally closed (active high) for terminals 11 and 12 in order to invert the sense of the
logic.

Summary Table - this table shows all six functions for the logical outputs (11, 12) at a
glance. Detailed descriptions of these functions, related parameters and settings, and
example wiring diagrams are in Chapter 4, starting on page 4–18.

“C” Function

Run-

time
Edit

Defaults

DOP,DRW,DOP+

Func.

Code

Name

Description

EU/

US

Units

Func.

Code

Name

C31

Terminal 11 active
state

Select logic convention, two
option codes:
00 ...normally open [NO]
01 ...normally closed [NC]

00

F-35

OUT-TM
O/C-1

C32

Terminal 12 active
state

Select logic convention, two
option codes:
00 ...normally open [NO]
01 ...normally closed [NC]

00

F-35

OUT-TM
O/C-2

C33

Alarm relay active
state

Select logic convention, two
option codes:
00 ...normally open [NO]
01 ...normally closed [NC]

01

F-35

OUT-TM
O/C-RY

Output Function Summary Table

Option

Code

Terminal

Symbol

Function Name

Description

00

RUN

Run signal

ON

when inverter is in Run Mode

OFF

when inverter is in Stop Mode

01

FA1

Frequency arrival
type 1 signal

ON

when output to motor is at the set frequency

OFF

when output to motor is off, or in any accelera-
tion or deceleration ramp

02

FA2

Frequency arrival
type 2 signal

ON

when output to motor is at or above the set
frequency, even if in accel. or decel. ramps

OFF

when output to motor is off, or at a level below
the set frequency

03

OL

Overload advance
notice signal

ON

when output current is more than the set thresh-
old for the overload signal

OFF

when output current is less than the set threshold
for the overload signal

04

OD

Output deviation for
PID control

ON

when PID error is more than the set threshold for
the deviation signal

OFF

when PID error is less than the set threshold for
the deviation signal