L100 Inverter Specifications

G

e

tt

in

g S

tar

te

d

1–6

General Specifications

The following table applies to all L100 inverters.

Item

General Specifications

Protective housing *1

IP20

Control method

Sine wave pulse-width modulation (PWM) control

Output frequency range *4

0.5 to 360 Hz

Frequency accuracy

Digital command: 0.01% of the maximum frequency
Analog command: ±0.2% of the maximum frequency (25

°

C ± 10

°

C)

Frequency setting resolution

Digital: 0.1 Hz; Analog: max. frequency/1000

Volt./Freq. characteristic

V/F optionally variable, V/F control (constant torque, reduced torque)

Overload current rating

150%, 60 seconds

Acceleration/deceleration time

0.1 to 3000 sec., (linear accel/decel), second accel/decel setting available

Input
signal

Freq.
setting

Operator panel

Up and Down keys / Value settings

Potentiometer

Analog setting

External signal *6

0 to 10 VDC (input impedance 10k Ohms), 4 to 20 mA (input impedance
250 Ohms), Potentiometer (1k to 2k Ohms, 2W)

FWD/
REV
Run

Operator panel

Run/Stop (Forward/Reverse run change by command)

External signal

Forward run/stop, Reverse run/stop

Intelligent input
terminal

FW (forward run command), RV (reverse run command), CF1~CF4 (multi-
stage speed setting), JG (jog command), 2CH (2-stage accel./decel.
command), FRS (free run stop command), EXT (external trip), USP (startup
function), SFT (soft lock), AT (analog current input select signal), RS (reset),
PTC (thermal protection)

Output
signal

Intelligent output terminal RUN (run status signal), FA1,2 (frequency arrival signal), OL (overload

advance notice signal), OD (PID error deviation signal), AL (alarm signal)

Frequency monitor

PWM output; Select analog output frequency monitor, analog output current
monitor or digital output frequency monitor

Alarm output contact

ON for inverter alarm (1C contacts, both normally open or closed avail.)

Other functions

AVR function, curved accel/decel profile, upper and lower limiters, 16-stage
speed profile, fine adjustment of start frequency, carrier frequency change
(0.5 to 16 kHz) frequency jump, gain and bias setting, process jogging,
electronic thermal level adjustment, retry function, trip history monitor

Protective function

Over-current, over-voltage, under-voltage, overload, extreme high/low
temperature, CPU error, memory error, ground fault detection at startup,
internal communication error, electronic thermal

Operat-
ing
Environ-
ment

Ambient storage humidity -10 to 50

°

C (*7) / -25 to 70

°

C (*8) / 20 to 90% humidity (non-condensing)

Vibration *9

5.9 m/s

2

(0.6G), 10 to 55 Hz

Location

Altitude 1,000 m or less, indoors (no corrosive gasses or dust)

Coating color

Light purple, cooling fins in base color of aluminum

Options

Remote operator unit, copy unit, cables for the units, dynamic braking unit,
braking resistor, AC reactor, DC reactor, noise filter, DIN rail mounting

Technologies Inc.