Setting
Explanation
Int Free Run
Internal timecode will be generated regardless of the recording
mode.
The internal timecode can be set manually using the following
operations:
•
•
Restarting internal timecode with a specified value
Timecode will always be output from the TIMECODE OUT jack.
Int Record Run
Internal timecode will be generated only when recording.
The internal timecode can be set manually using the following
operations:
•
•
Restarting internal timecode with a specified value
When switching from another mode, or when recording stops, the
internal timecode will stop at the last value.
Int RTC Run
Internal timecode will be generated regardless of the recording
mode.
In the following situations, the internal timecode will be synchronized
(jammed) with the RTC (internal clock):
• At startup
• When “Date/Time (RTC)” has changed
(→
)
• When switching to this timecode mode
Timecode will always be output from the TIMECODE OUT jack.
Ext
The internal timecode will chase the external timecode.
You can also enable the automatic generation of internal timecode
when there is no external timecode.
internal timecode when no external timecode is input
Ext Auto Rec
The internal timecode will chase the external timecode.
You can also enable the automatic generation of internal timecode
when there is no external timecode.
internal timecode when no external timecode is input
Recording starts automatically when external timecode input is
detected. Recording stops automatically when external timecode
stops.