beautypg.com

4 lens motors, Lens motors – ARRI ALEXA 35 Body & PL Mount Set (LBUS) User Manual

Page 95

background image

Lens & Electronic Control System (ECS)

95

22.4 Lens Motors

The camera supports the use of cforce mini, cforce plus and cforce mini RF lens motors. Lens motors

are connected to the LBUS connector of the camera and/or the lens mount and can be daisy chained.

For more information about lens motors, please download the lens motor user manuals from the

Lens Motors

section of the ARRI website.

Motor Calibration

CAUTION

Rotating Lens Motor

Risk of crushing fingers and capturing and unraveling long hair, jewelry and/or clothing.

Make sure that the lens motor is properly attached to the lens.
Do not touch the lens motor gears while they are moving.
Keep hair and loose clothing away from the motor gear teeth.
Keep cables connected to the camera away from the motor gear teeth.
Do not trigger a calibration unless all connected motors are attached to the lens.

After a lens motor has been connected to the camera, it must first be calibrated before it can be used.

The camera indicates the calibration request by displaying an orange CAL icon on the HOME

screen as well as in the Status Info. The icon turns gray once calibration is in progress, and

expires when calibration has finished.

► Select

MENU > Lens + ECS > Calibrate All Motors

to start calibration of all connected lens motors.

Alternatively, motor calibration can be triggered via the hand unit or the motor itself.

Motor Torque

► Select

MENU > Lens & ECS > LBUS Lens Motor Configuration Focus / Iris / Zoom Motor Torque

to

set the torque of a lens motor in the range of

1

(the lowest torque) to

4

(the highest torque).

Motor Direction

► Select

MENU > Lens & ECS > LBUS Lens Motor Configuration Focus / Iris / Zoom Motor Direction

to set the motor direction between

Left

and

Right

.

Use

Left

if a lens motor is to the left of the lens, use

Right

if it is to the right.

Teeth Count

The motor teeth count setting is only active when an LDA lens table is active and is used to assure

correct lens table mappings when using a different motor gear than the one the lens table was initially

created with. The number of teeth can be read on the gear wheel of the motor.
► Select

MENU > Lens & ECS > LBUS Lens Motor Configuration Focus / Iris / Zoom

Motor Teeth Count

to set the teeth count.

Following options are available:

Auto
40t
50t
60t

The camera determines the teeth count during motor calibration.

The motor is equipped with a 40 tooth gear.

The motor is equipped with a 50 tooth gear.

The motor is equipped with a 60 tooth gear.