beautypg.com

4 camera body overview, Camera body overview, 4camera body overview – ARRI ALEXA 35 Body & PL Mount Set (LBUS) User Manual

Page 9

background image

Camera Body Overview

9

4

Camera Body Overview

Camera Front

1

SERIAL Connector

2

LBUS Connector (on Lens Mount)

3

VF 1 Viewfinder Connector

4

Lens Mount (here: LPL Mount (LBUS))

5

LBUS Connector

SERIAL Connector (4-pin LEMO)

The SERIAL connector is used to connect distance measurement devices such as ARRI UDM-1, CE

CineTape Measure or Focus Bug directly to the camera and receives data from and provides power

to the distance measuring device. The SERIAL connector outputs regulated 12.0 V with a maximum

current of 200 mA.

VF 1 Viewfinder Connector (CoaXPress)

The camera uses an industrial CoaXPress interface with an ARRI custom connector to connect the

MVF-2 viewfinder with the camera. The interface transmits power, video and control data. The VF 1

connectors supports cable lengths of up to 5 m (16.4 ft). The VF connector supports hot plugging and

comes without a key, so the viewfinder cables plug in regardless of the connector's orientation.

LBUS Connector (4-pin LEMO)

Both LBUS connectors are used to connect daisy chainable LBUS devices of the ECS Electronic

Control System (lens motors, ARRI Master Grips, ARRI OCU-1, RIA-1...) to the camera and supply

regulated 24.0 V with a maximum current of 4.0 A.

ADVICE

Do not connect both LBUS ports (body and lens mount) of the ALEXA 35 in a daisy chain

and thus form a loop, you may experience problems such as the camera shutting down.