beautypg.com

8 evf and flip-out monitor settings, Evf and flip-out monitor settings – ARRI ALEXA 35 Body & PL Mount Set (LBUS) User Manual

Page 72

background image

Monitoring

72

444 3G HD

Images are output according to SMPTE ST 424:2012

Available frame rates are 23.976p, 24p, 25p, 29.97p and 30p

422 6G UHD

Images are output according to SMPTE ST 2081-10:2015

Available frame rates are 23.976p, 24p, 25p, 29.97p and 30p

422 12G UHD

Images are output according to SMPTE ST 2048-1

Available frame rates are 48p, 50p, 59.94p and 60p

444 12G UHD

Images are output according to SMPTE 2082-10:2015

Available frame rates are 23.976p, 24p, 25p, 29.97p and 30p

Info

: 48p may not be supported by some SDI devices, as this is not a defined frame rate according

to the SMPTE standard.

Info:

6G / 12G formats are not available when the recording resolution is set to 2K or HD.

SDI Frame Rate

The SDI frame rate determines the number of images that are output per second on the SDI output(s).

It should be set equal to the sensor frame rate. If the frame rate is lower than the sensor frame rate,

frame drops will occur. If it is higher, duplicate images will be output. The available SDI frame rates

depend on the selected SDI format.
► Select

MENU > Monitoring > SDI > SDI 1 Frame Rate

to set the frame rate of the SDI 1 output.

► Select

MENU > Monitoring > SDI > SDI 2 Frame Rate

to set the frame rate of the SDI 2 output.

SDI 3G Level

For the 3G SDI formats, you can choose whether to use 3G level A or B. Refer to the instructions of

your connected devices to decide which 3G level to use.
► Select

MENU > Monitoring > SDI > SDI 1 3G Level

to set the 3G level for the SDI 1 output.

► Select

MENU > Monitoring > SDI > SDI 2 3G Level

to set the 3G level for the SDI 2 output.

Hide Messages

User messages displayed as overlays on the monitoring outputs are primarily relevant for the camera

team and do not necessarily need to be displayed on the SDI output that other crew members are

viewing. The camera offers the possibility to suppress all user messages on a selected SDI output.
► Select

MENU > Monitoring > SDI > SDI 1 Processing > Hide Messages

to hide user messages on

the SDI 1 output.

► Select

MENU > Monitoring > SDI > SDI 2 Processing > Hide Messages

to hide user messages on

the SDI 2 output.

14.8 EVF and Flip-out Monitor Settings

EVF Brightness

The brightness of the EVF is adjustable with values 120, 200 and 300 (Nits).
► Select

MENU > Monitoring > VF > Settings > EVF Brightness

to set the brightness of the viewfinder

OLED between

120

,

200

or

300

.

Info:

When

VF Processing

is configured for

Look (EVF: HDR, Mon: SDR),

, the EVF brightness is

fixed to 500 nits and can't be changed.

EVF Power

► Select

MENU > Monitoring > VF > Settings > EVF Power