72
444 3G HD
Images are output according to SMPTE ST 424:2012
Available frame rates are 23.976p, 24p, 25p, 29.97p and 30p
422 6G UHD
Images are output according to SMPTE ST 2081-10:2015
Available frame rates are 23.976p, 24p, 25p, 29.97p and 30p
422 12G UHD
Images are output according to SMPTE ST 2048-1
Available frame rates are 48p, 50p, 59.94p and 60p
444 12G UHD
Images are output according to SMPTE 2082-10:2015
Available frame rates are 23.976p, 24p, 25p, 29.97p and 30p
Info
: 48p may not be supported by some SDI devices, as this is not a defined frame rate according
to the SMPTE standard.
Info:
6G / 12G formats are not available when the recording resolution is set to 2K or HD.
SDI Frame Rate
The SDI frame rate determines the number of images that are output per second on the SDI output(s).
It should be set equal to the sensor frame rate. If the frame rate is lower than the sensor frame rate,
frame drops will occur. If it is higher, duplicate images will be output. The available SDI frame rates
depend on the selected SDI format.
► Select
MENU > Monitoring > SDI > SDI 1 Frame Rate
to set the frame rate of the SDI 1 output.
► Select
MENU > Monitoring > SDI > SDI 2 Frame Rate
to set the frame rate of the SDI 2 output.
SDI 3G Level
For the 3G SDI formats, you can choose whether to use 3G level A or B. Refer to the instructions of
your connected devices to decide which 3G level to use.
► Select
MENU > Monitoring > SDI > SDI 1 3G Level
to set the 3G level for the SDI 1 output.
► Select
MENU > Monitoring > SDI > SDI 2 3G Level
to set the 3G level for the SDI 2 output.
Hide Messages
User messages displayed as overlays on the monitoring outputs are primarily relevant for the camera
team and do not necessarily need to be displayed on the SDI output that other crew members are
viewing. The camera offers the possibility to suppress all user messages on a selected SDI output.
► Select
MENU > Monitoring > SDI > SDI 1 Processing > Hide Messages
to hide user messages on
the SDI 1 output.
► Select
MENU > Monitoring > SDI > SDI 2 Processing > Hide Messages
to hide user messages on
the SDI 2 output.
14.8 EVF and Flip-out Monitor Settings
EVF Brightness
The brightness of the EVF is adjustable with values 120, 200 and 300 (Nits).
► Select
MENU > Monitoring > VF > Settings > EVF Brightness
to set the brightness of the viewfinder
OLED between
120
,
200
or
300
.
Info:
When
VF Processing
is configured for
Look (EVF: HDR, Mon: SDR),
, the EVF brightness is
fixed to 500 nits and can't be changed.
EVF Power
► Select