Sie diagnostics – ProSoft Technology PLX31-EIP-SIE User Manual

Page 181

background image

PLX3x Series

SIE Protocol

Ethernet and Serial Gateways

User Manual

ProSoft Technology, Inc.

Page 181 of 218

September 17, 2014

9.3

SIE Diagnostics

The best way to troubleshoot the SIE driver is to use ProSoft Configuration
Builder to access the diagnostic capabilities of the gateway through the Ethernet
debug port. For instructions on how to access Diagnostics, see

Using

Diagnostics in ProSoft Configuration Builder

(page 36).

9.3.1 Client Command Errors

Each SIE Client has an associated status data area located in the

gateway’s

upper memory. The Data Map functionality of the gateway can be used to map
this data into the normal user data range of the gateway

’s database. See

Using

the CommonNet Data Map

(page 25).

The following table lists the starting addresses in upper memory where the status
data for each Client can be found.

Client

Gateway Starting Register for Status Data

0

21100

1

21125

2

21151

18

21568

19

21594


The following table describes the content of each Client’s status data area.

Word Offset

Description

0

Command Request Count

1

Command Response Count

2

Command Error Count

3

Number of Request Packets

4

Number of Response Packets

5

Errors Sent

6

Errors Received

7

Configuration Error Word

8

Current Error

9

Last Error

10 to 25

Command List Errors (16 per Client)

For every command that has an error, the gateway automatically sets the poll
delay parameter to 30 seconds. This instructs the gateway to wait 30 seconds
before it attempts to issue the command again.