SIE Protocol

PLX3x Series

User Manual

Ethernet and Serial Gateways

Page 176 of 218

ProSoft Technology, Inc.

September 17, 2014

Parameter

Value

Description

Rack

0 to 999

Rack number of the S7-300, S7-400 or S7-1200 CPU.

Note: Rack number is not used for the S7-200 CPU.

Slot

0 to 12

Slot number of the S7-300, S7-400 or S7-1200 CPU.

Note: Slot number is not used for the S7-200 CPU.

TSAP

TSAP of the S7-200 CPU. This can be found in the Siemens
STEP 7 MicroWIN software.

Note: TSAP is not used for the S7-300, S7-400 and S7-1200.

Func Type

Read
Write

This parameter can either be Read or Write.

Data Type

BOOL
BYTE
DINT
REAL
INT
TIME
COUNT

This parameter can be BOOL, BYTE, DINT, REAL, INT, TIME,
or COUNT.

Address
Type

INPUT
OUTPUT
FLAG
TIMER
COUNTER
DB

This parameter can be INPUT, OUTPUT,FLAG, TIMER,
COUNTER or DB (Data Block).

DB Number

0 to 32767

Specifies the Data Block number to be used with the command.

Note: DB Number is only used when the Address Type is set to
DB.

Address

Address of the data in the Siemens device. For Read or Write
operations using the INT, DINT, REAL or BYTE Data Types, the
address is a byte address.

For Read or Write operations using the BOOL Data Type, the
address is a bit address. Please see below for notes on
addressing.