User’s Manual of WGSW-28040 / 28040P / 28040P4
62
request the current values.
The allowed string length is 1 to 16.
• Write View Name
The name of the MIB view defining the MIB objects for which this request may
potentially SET new values.
The allowed string length is 1 to 16.
Buttons
: Click to add a new access entry.
: Check to delete the entry.
4.2.8.5 SNMP Community
Configure SNMP Community on this page. The SNMP Community screen in
Figure 4-2-24 & Figure 4-2-25
appears.
Figure 4-2-24 Community Setting page screenshot
The page includes the following fields:
Object
Description
•
Community Name
Indicates the community read/write access string to permit access to SNMP
agent.
The allowed string length is 0 to 16.
• Group Name
A string identifying the group name that this entry should belong to.
The allowed string length is 1 to 16.
• View Name
A string identifying the view name that this entry should belong to.
The allowed string length is 1 to 16.
•
Access Right
Indicates the SNMP community type operation. Possible types are:
RO=Read-Only: Set access string type in read-only mode.
RW=Read-Write: Set access string type in read-write mode.