Chapter 2: Hardware and Software Setup
Syncro CS 9286-8e Two-Server Cluster Hardware Setup
5.
Ground yourself, and then place the Syncro CS controller on a flat, clean, static-free surface.
NOTE
If you want to replace a bracket, refer to "Replacing Brackets" on
MegaRAID SAS+SATA RAID Controllers Quick Installation Guide
for
instructions.
6.
Take the cable included with the kit, and insert one end of it into the 9-pin connector on the remote CVPM02
module, as shown in the following figure.
NOTE
The CVPM02 module is a super-capacitor pack that provides power for
the cache offload capability to protect cached data in case of host
power loss or server failure.
Figure
3 Connecting the Cable to the Remote CVPM02 Module
7.
Mount the CVPM02 module to the inside of the server chassis, as shown in
. Refer to the server
documentation to determine the exact method of mounting the module.
NOTE
Because server chassis design varies from vendor to vendor, no
standard mounting option exists for the CVPM02 module that is
compatible with all chassis configurations. Authorized resellers and
chassis manufacturers might have recommendations for the location
J4A2
LSI Test header
Reserved for Avago use.
J5A1
Serial UART connector for the expander
Reserved for Avago use.
J6A1
Serial UART connector for the expander
Reserved for Avago use.
Table
1 Syncro CS 9286-8e Controller Jumpers (Continued)
Jumper/
Connector
Type
Description
3_01853-00
CVPM02
Module
CVFM03
Module
J2A1