Example of migrate output for single to raid 1 – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 98

Chapter 2. CLI Syntax Reference
90
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
3ware CLI> /c0 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
---------------------------------------------------------------------------
u0 RAID-5 OK - - 64K 596.004 RiW OFF
u2 SPARE OK - - - 149.042 - OFF
u3 Migrator MIGRATING - 39 - 149.001 RiW OFF
VPort Status Unit Size Blocks Serial
-----------------------------------------------------------------------
p0 OK u0 149.05 GB 312581808 WD-WCANM1771318
p1 OK u0 149.05 GB 312581808 WD-WCANM1757592
p2 OK u0 149.05 GB 312581808 WD-WCANM1782201
p3 OK u0 149.05 GB 312581808 WD-WCANM1753998
p4 OK u2 149.05 GB 312581808 WD-WCANM1766952
p5 OK u3 149.05 GB 312581808 WD-WCANM1882472
p6 OK u0 149.05 GB 312581808 WD-WCANM1883862
p7 OK u3 149.05 GB 312581808 WD-WCANM1778008
p8 OK - 149.05 GB 312581808 WD-WCANM1770998
p9 NOT-PRESENT - - - -
p10 OK u3 149.05 GB 312581808 WD-WCANM1869003
p11 OK u3 149.05 GB 312581808 WD-WCANM1762464
3ware CLI> /c0/u3 show
Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
------------------------------------------------------------------------
u3 Migrator MIGRATING - 39 - - -
su3 RAID-1 OK - - - - 149.001
su3-0 DISK OK - - p5 - 149.001
su3-1 DISK OK - - p7 - 149.001
su3/v0 Volume - - - - - 149.001
du3 RAID-10 OK - - - 16K 298.002
du3-0 RAID-1 OK - - - - -
du3-0-0 DISK OK - - p5 - 149.001
du3-0-1 DISK OK - - p7 - 149.001
du3-1 RAID-1 OK - - - - -
du3-1-0 DISK OK - - p10 - 149.001
du3-1-1 DISK OK - - p11 - 149.001
du3/v0 Volume - - - - - 149.001
Example of migrate output for Single to RAID 1
The migration path from RAID type Single to RAID 1 is a special case.
Because the single unit becomes a mirrored array, technically, this is not a
migration. As a result, this command shows a different status than other
migration paths. In addition, the status of the newly specified disk shows
DEGRADED until the “migration/rebuild” is complete.
For example, below is a system with two migrating units, /c0/u0 and /c0/u1.
Unit u0 is migrating from a RAID 10 to a RAID 0 unit, while unit u1 is
migrating from Single to a RAID 1, initiated by the following commands:
/c0/u0 migrate type=raid0
/c0/u1 migrate type=raid1 disk=5
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)