C x show drivestatus – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 46

Chapter 2. CLI Syntax Reference
38
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
p6 0 0 0 0 0 0 0
Note:
Depending on the amount of I/O and the rate or duration of the data
transfer, overflow of the buffers containing this data can occur. In this case,
the overflow is marked with “#######”, as shown in the example below. If
overflow occurs, you might want to return the counters to zero by using the
clear command, “/cx/px set dpmstat=clear [type=ra|lct|ext]” on page 101.
Example of drive statistics overflow:
//localhost> /c3 show dpmstat type=ext
Extended Drive Statistics for /c3 ...
Sectors Commands
----------------------------------- --------------------------------------
Port Read Write Write-FUA Read Write Write-FUA Flush
---------------------------------------------------------------------------
p0 ######## 0 158838656 158838720 0 0 0
p2 ######## ######## ######## ######## ######## ######## ########
p3 ######## 0 0 0 0 0 0
p6 0 0 0 0 0 0 0
/cx show drivestatus
The /cx show drivestatus command shows a list of drives and their port
assignment, status, the unit with which they are associated, their size in
gigabytes and blocks, and the serial number assigned by the drive
manufacturer. (Definitions of the drive statuses are available in the 3ware
SATA+SAS RAID Controller Card Software User Guide, Version 10.2.)
Example:
//localhost> /c2 show drivestatus
VPort Status Unit Size Type Phy Encl-Slot Model
--------------------------------------------------------------------------
p0 OK u0 34.25 GB SAS - /c2/e0/slt0 MAXTOR ATLAS15K2_36
p1 OK u0 34.25 GB SAS - /c2/e0/slt1 MAXTOR ATLAS15K2_36
p2 OK u0 34.25 GB SAS - /c2/e0/slt2 MAXTOR ATLAS15K2_36
p3 OK u0 34.18 GB SAS - /c2/e1/slt0 HITACHI HUS151436VL
p4 OK u0 34.18 GB SAS - /c2/e1/slt1 HITACHI HUS151436VL
p5 OK u0 34.18 GB SAS - /c2/e1/slt2 HITACHI HUS151436VL
p6 OK u0 34.25 GB SAS - /c2/e0/slt3 MAXTOR ATLAS15K2_36
p7 OK u0 34.25 GB SAS - /c2/e0/slt4 MAXTOR ATLAS15K2_36
p8 OK u0 34.25 GB SAS - /c2/e0/slt5 MAXTOR ATLAS15K2_36
p9 OK u0 34.25 GB SAS - /c2/e0/slt6 MAXTOR ATLAS15K2_36
p10 OK u0 34.18 GB SAS - /c2/e1/slt3 HITACHI HUS151436VL
p11 OK u0 34.18 GB SAS - /c2/e1/slt4 HITACHI HUS151436VL
p12 OK u0 34.18 GB SAS - /c2/e1/slt5 HITACHI HUS151436VL
p13 OK u0 34.18 GB SAS - /c2/e1/slt6 HITACHI HUS151436VL
p14 OK u0 34.25 GB SAS - /c2/e0/slt7 MAXTOR ATLAS15K2_36
p15 OK u0 34.25 GB SAS - /c2/e0/slt8 MAXTOR ATLAS15K2_36
p16 OK u0 34.25 GB SAS - /c2/e0/slt9 MAXTOR ATLAS15K2_36
p17 OK u0 34.25 GB SAS - /c2/e0/slt10 MAXTOR ATLAS15K2_36
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)