Cx rescan [noscan – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 65

Controller Object Commands
www.lsi.com/channel/products
57
Volumes 0 through 3 are carved using the first four sizes, as specified.
Volumes 4, 5, and 6 are the autocarved volumes (1024 GB each). Volume 6 is
the remainder of the carve size.
//localhost> /c2 add type=raid0 disk=0:1:2:4:5:6:
7 vol=2000:500:1024:700
Creating new unit on controller /c2 ... Done. The new unit is /
c2/u0.
Setting default Command Queuing Policy for unit /c2/u0 to [on]
... Done.
Setting write cache=ON for the new unit ... Done.
After the unit creation, a subsequent show command for the unit shows the
volume sizes:
//localhost> /c2/u0 show
Unit UnitType Status %RCmpl %V/I/M Port Stripe Size(GB)
------------------------------------------------------------------------
u0 RAID-0 OK - - - 256K 6519.19
u0-0 DISK OK - - p0 - 931.312
u0-1 DISK OK - - p1 - 931.312
u0-2 DISK OK - - p2 - 931.312
u0-3 DISK OK - - p4 - 931.312
u0-4 DISK OK - - p5 - 931.312
u0-5 DISK OK - - p6 - 931.312
u0-6 DISK OK - - p7 - 931.312
u0/v0 Volume - - - - - 2000
u0/v1 Volume - - - - - 500
u0/v2 Volume - - - - - 1024
u0/v3 Volume - - - - - 700
u0/v4 Volume - - - - - 1024
u0/v5 Volume - - - - - 1024
u0/v6 Volume - - - - - 247.188
/cx rescan [noscan]
The /cx rescan command instructs the controller to rescan all ports or vports,
and phys and reconstitute all units. The controller updates its list of disks, and
attempts to read every Disk Configuration Block (DCB) in order to
reassemble its view of logical units. Any newly found units or drives are
listed.
noscan is used to prevent the operating system from being notified of the unit
discovery. The default is to inform the operating system.
Example:
//localhost> /c1 rescan
Note:
If you are adding new drives, add them physically before issuing the rescan
commands. If you want to hot-swap drives without first powering down the system,
use hot-swap bays. This helps prevent system hangs and electrical damage.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)