Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 108

Chapter 2. CLI Syntax Reference
100
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
6 6 0
7 7 0
8 8 0
9 9 0
10 10 0
11 20 204
12 30 190
13 40 161
14 50 136
15 60 130
16 70 112
17 80 94
18 90 80
19 100 540
20 200 95
21 300 42
22 400 11
23 500 2
24 600 2
25 700 0
26 800 0
27 900 0
28 1000 0
29 2000 0
30 3000 0
31 4000 0
32 5000 0
33 6000 0
34 7000 0
35 8000 0
36 9000 0
37 10000 0
38 10000+ 0
Note that in the example above, there is a set of 38 “Bins” (shown in the first
column) and each bin has associated with it a different Response Time
category (shown in the second column). There are no commands with
response times of 10 ms or less, and there are 204 commands with response
times between 10 ms and 20 ms (bin 11). Each time that an I/O or command
sends to a drive, the response time for that I/O increments the bin associated
with that response time.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)