Cx/ex/almx show, Cx/ex/almx set alarm=mute|unmute|off – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 128

Chapter 2. CLI Syntax Reference
120
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
/cx/ex/almx show
The /cx/ex/almx show command applies only to 9750 and 9690SA
controllers. For the 9650SE, simply drop the prepended controller name in the
command and use /ex.
The /cx/ex/almx show command shows information about the specified
enclosure alarm. The possible status values are OK, FAIL, NOT-
INSTALLED, and ACTIVATED. The status values are described below. The
possible values for State are ON and OFF. The possible values for Audibility
are UNMUTE and MUTED.
Possible status values and their descriptions are as follows:
OK – Alarm device is functional and operational.
FAIL – Alarm device has malfunctioned and is not operational.
NOT-INSTALLED – Alarm device has not been installed.
ACTIVATED - Alarm device is functional, and an error condition has been
detected. This is a visual indication for the alarm, in addition to the sound. If
you mute the sound, the visual indication remains.
Example:
//localhost> /c0/e0/alm0 show
Alarm Status State Audibility
---------------------------------------------------
alm0 ACTIVATED ON UNMUTE
/cx/ex/almx set alarm=mute|unmute|off
The /cx/ex/almx set alarm command applies only to 9750 and 9690SA
controllers. For the 9650SE, simply drop the prepended controller name in the
command and use /ex.
The /cx/ex/almx set alarm command controls the audibility and state of the
enclosure alarm. It provides the ability to silence an activated alarm. It also
gives you the option to mute or unmute the alarm setting.
You can also use this command to prevent an audible alarm from sounding, in
the case where a known condition will set off the alarm, by muting the alarm
in advance.
If an error condition or degraded state is detected, the enclosure alarm or
buzzer sounds. To silence the alarm, you can either set the state of the alarm to
off, or you can mute the alarm.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)