Cx show verifyrate – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 60

Chapter 2. CLI Syntax Reference
52
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
For a more complete discussion of background task modes, see “Working
with the Background Task Mode” in the 3ware SATA+SAS RAID Controller
Card Software User Guide, Version 10.2
Example:
//localhost> /c1 show verifymode
/c1 Verify background task mode = Low Latency
Related commands:
/cx show verifyrate
The /cx show verifyrate command shows the current verify task rate of the
specified controller. The verify task rate sets the verify execution priority
relative to I/O operations.
This task rate is in the range of [1..5], where 5 denotes the setting of fastest
background task and slowest I/O, as follows:
5 = fastest verify; slowest I/O
4 = faster verify; slower I/O
3 = balanced between verify and I/O
2 = faster I/O; slower verify
1 = fastest I/O; slowest verify
Example:
//localhost> /c1 show verifyrate
/c1 Verify task rate = 4 (faster verify; slower I/O)
Related commands:
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)