Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 114

Chapter 2. CLI Syntax Reference
106
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
/cx/bbu show status
The /cx/bbu show status command shows the status of the BBU. Possible
values are as follows:
Testing.
A battery test is currently in progress. This test can take up to 24
hours to complete. During the test, the BBU is
not
capable of backup
operation and the write cache might be disabled, deending on the unit’s
Storsave setting. If the test is completed without detection of a BBU error and
the BBU status changes to WeakBat or OK, the write cache is re-enabled. If a
Fault, Failed, or Error occurs during the test, the write cache remains in the
disabled state until you resolve the problem.
Charging.
The BBU is currently charging the battery. The BBU automatically
starts charging whenever necessary. During charging, the BBU is
not
capable
of backup operation and the write cache might be disabled, depending on the
unit’s Storsave setting. After the test is completed successfully and the BBU
status changes to OK, the write cache is re-enabled. If a FAULT or ERROR
occurs during the test, the write cache remains in the disabled state until you
resolve the problem.
Fault.
A battery fault is detected. The BBU is not capable of backup operation
and the write cache might be disabled, depending on the unit’s Storsave
setting. To re-enable write cache, replace the battery and/or the BBU board as
soon as possible.
Error.
A BBU error is detected. The BBU is not capable of backup operation
and the write cache might be disabled, depending on the unit’s Storsave
setting. To re-enable write cache, replace the battery and/or the Battery
Backup Unit as soon as possible.
Failed.
The battery failed a test. In this state, the BBU is not capable of
backup operation and the write cache is disabled. To re-enable write cache,
replace the battery and/or the BBU as soon as possible.
WeakBat.
The BBU is functioning normally and is online and capable of
backing up the write cache. However, the battery is weak and needs to be
replaced.
OK.
The BBU is ready, online, and capable of backing up the write cache. The
unit’s write cache is automatically reenabled, if applicable.
A dash (-) indicates that a battery or a BBU is not installed.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)