Cx/bbu test [quiet, Cx/bbu enable, Cx/bbu disable [quiet – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 116

Chapter 2. CLI Syntax Reference
108
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
/c1/bbu Battery Temperature Status = OK
/c1/bbu Battery Temperature Value = 25 deg C
/c1/bbu Estimated Backup Capacity = 241 Hours
/c1/bbu Last Capacity Test = 22-Jun-2008
/c1/bbu Battery Installation Date = 20-Jun-2008
/c1/bbu Bootloader Version = BBU 0.02.00.002
/c1/bbu PCB Revision = 65
/cx/bbu test [quiet]
The /cx/bbu test command starts the battery capacity test. The test can take
up to 24 hours to complete. During the test, the BBU is not capable of backup
operation and the write cache of all units attached to that controller is
disabled. After the test is completed successfully and the BBU status returns
to OK, the write cache is re-enabled.
Asynchronous Event Notification (AEN) messages are also generated by
controllers to notify you of the command status.
You can check for AENs with the controller alarms command
/cx show alarms [reverse] or with the commands /cx show events [reverse]
or /cx show AENs [reverse]. Using the reverse attribute lists the most recent
AEN message at the top of the list. (For a list of all AENs, see the user guide
that came with your 3ware RAID controller.)
/cx/bbu enable
The /cx/bbu enable command enables BBU detection on the controller. If the
BBU is Ready, the controller utilizes BBU functionality in the event of a
power failure.
/cx/bbu disable [quiet]
The /cx/bbu disable command disables BBU detection on the controller.
When disabled, the controller ignores the existence of the BBU and shows
that no BBU is installed even if a BBU is physically attached.
Note:
Once started, the test can not be terminated before it completes. Write
cache cannot be enabled until the test completes.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)