Cx show all – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 50

Chapter 2. CLI Syntax Reference
42
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
available in the 3ware SATA+SAS RAID Controller Card Software User
Guide, Version 10.2.)
Example:
//localhost> /c2 show unitstatus
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
-------------------------------------------------------------------------
u0 RAID-5 OK - - 64K 596.004 ON OFF
u1 RAID-0 OK - - 64K 298.002 ON OFF
u2 SPARE OK - - - 149.042 - OFF
u3 RAID-1 OK - - - 149.001 ON OFF
/cx show all
The /cx show all command shows the current setting of all of the following
attributes on the specified controller: achip, allunitstatus, autocarve, bios,
driver, drivestatus, firmware, memory, model, monitor, numports, numunits,
numdrives, ondegrade, pcb, pchip, serial, spinup, stagger, and unitstatus.
Example for 9750-8e:
/c1 Driver Version = 5.01.00.018
/c1 Model = 9750-8e
/c1 Available Memory = 488MB
/c1 Firmware Version = FH9X 5.11.00.008
/c1 Bios Version = BE9X 5.11.00.002
/c1 Boot Loader Version = BT9X 6.00.00.003
/c1 Serial Number = C297BP269
/c1 PCB Version = Rev 001
/c1 PCHIP Version = B2
/c1 ACHIP Version = 05000900
/c1 Controller Phys = 8
/c1 Connections = 23 of 128
/c1 Drives = 23 of 128
/c1 Units = 3 of 128
/c1 Active Drives = 17 of 128
/c1 Active Units = 3 of 32
/c1 Max Drives Per Unit = 32
/c1 Total Optimal Units = 3
/c1 Not Optimal Units = 0
/c1 Disk Spinup Policy = 1
/c1 Spinup Stagger Time Policy (sec) = 1
/c1 Auto-Carving Policy = off
/c1 Auto-Carving Size = 2048 GB
/c1 Auto-Rebuild Policy = on
/c1 Rebuild Mode = Adaptive
/c1 Rebuild Rate = 1
Note:
If an asterisk (*) appears next to the status of a unit, there is an error on one
of the drives in the unit. This feature provides a diagnostic capability for potential
problem drives. The error might not be a repeated error, and can be caused by an
ECC error, SMART failure, or a device error. Rescanning the controller clears the
drive error status when the condition no longer exists.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)