Cx/ux show attribute [attribute – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 82

Chapter 2. CLI Syntax Reference
74
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
/cx/ux show attribute [attribute ...]
The /cx/ux show attribute command shows the current setting of one or more
specified attributes. If you specify an invalid attribute, the loop terminates.
Possible attributes are: initializestatus, name, autoverify, rdcache, wrcache,
ignoreECC, identify, qpolicy, parity, rapidrecovery, rebuildstatus, serial,
status, storsave, verifystatus, and volumes.
/cx/ux show autoverify
The /cx/ux show autoverify command shows the current autoverify setting of
the specified unit.
Example:
//localhost> /c0/u0 show autoverify
/c0/u0 Auto Verify Policy = off
/cx/ux show wrcache
The /cx/ux show wrcache command shows the current write cache state of
the specified unit.
Example:
//localhost> /c0/u0 show wrcache
/c0/u0 Write Cache State = on
/cx/ux show rdcache
The /cx/ux show rdcache command shows the current read cache state of the
specified unit.
The state of the read cache can be either Basic, Intelligent, or Off. This
command is supported with all RAID array types. For more information, see
“/cx/ux set rdcache=basic|intelligent|off” on page 82
Example:
//localhost> /c0/u0 show rdcache
/c0/u0 Read Cache = Intelligent
/cx/ux show identify
The /cx/ux show identify command is related to the /cx/ux set
identify=on|off
command. It shows the identify status of the specified unit
(either on or off).
Example:
//localhost> /c0/u0 show identify
/c0/u0 Identify status = on
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)