Cx set autodetect=on|off disk=|all – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 78

Chapter 2. CLI Syntax Reference
70
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
disconnect a drive (causing the controller to respond to it as a failed drive) and
then reconnect it, the controller automatically tries to use it again.
If the policy is off, spares are the only candidates for rebuild operations.
Example:
//localhost> /c0 set autorebuild=enable
Setting Auto-Rebuild Policy on /c0 to enable ... Done.
/cx set autodetect=on|off disk=
The /cx set autodetect command is associated with the staggered spinup
feature when hot-swapping drives. When staggered spinup is enabled (see
command /cx set spinup and /cx set stagger), during a reset or power on, the
controller spins up all detected drives with a delay between each spinup,
allowing the spread of power consumption on the power supply. When a drive
is hot-swapped, (as opposed to when it has just been powered on or reset), the
default behavior of the system is to automatically detect and immediately spin
up the drives. This command can change the default behavior and set the
controller to do a staggered spinup for hot-swapped drives.
autodetect=on|off enables or disables automatic detection of drives on the
controller’s ports for staggered spin-up.
disk=
If a port is empty (no drive is inserted), the echo message of the command
refers to a port. If there is already a drive inserted, the message refers to a
disk. The following example shows that autodetect has been set to off to
initiate staggered spin-up during hot-swapping, where port 3 is empty and
ports 5 and 6 contain newly-inserted drives.
Example:
//localhost>> /c0 set autodetect=off disk=3:5-6
Setting Auto-Detect on /c0 to [off] for port [3] and for disk
[5,6]... Done
If disk=all, then all of the drives or ports for that controller are specified. This
setting is only for direct attached drives and has no effect on drives behind an
expander.
Example:
//localhost>> /c0 set autodetect=off disk=all
Setting Auto-Detect on /c2 to [off] for all disks/ports... Done.
Note:
The autodetect setting cannot be shown in CLI, 3DM2, or 3BM.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)