C x show bios, C x show carvesize, C x show ctlbus – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 43: C x show driver

Controller Object Commands
www.lsi.com/channel/products
35
3. Smallest usable failed drive.
If the policy is disabled, only spare drives are used for an automatic rebuild
operation.
Example:
//localhost> /c0 show autorebuild
/c0 Auto-Rebuild Policy = on
/cx show bios
The /cx show bios command shows the BIOS version of controller /cx.
Example:
//localhost> /c0 show bios
/c0 BIOS Version = BG9X 2.x
/cx show carvesize
The /cx show carvesize command shows the maximum size of the volumes
that can be created if the autocarve policy is set to on. You can set the
carvesize between 1024 GB and 32768 GB (1 TB to 32 TB). Default
carvesize is 2048 GB (2 TB). For more information see, “/cx show autocarve”
on page 34.
Example:
//localhost> /c0 show carvesize
/c0 Autocarving Size = 2000 GB
/cx show ctlbus
The /cx show ctlbus command shows the controller host bus type, bus speed,
and bus width.
Example for 9690SA:
//localhost> /c2 show ctlbus
/c2 Controller Bus Type = PCIe
/c2 Controller Bus Width = 8 lanes
/c2 Controller Bus Speed = 2.5 Gbps/lane
/cx show driver
The /cx show driver command shows the device driver version associated
with controller
/cx.
Example:
//localhost> /c0 show driver
/c0 Driver Version = 3.x
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)