beautypg.com

Section 7 - ieee 488.2 (gpib) interface, 2 ieee 488 (gpib) bus protocol, See section 7) – KEPCO KLP Series Developers Guide, Rev 3 User Manual

Page 91: D section 7, ieee 488.2 (gpib) inter- face

background image

KLP-DEV 041213

7-1

SECTION 7 - IEEE 488.2 (GPIB) INTERFACE

7.1

DIGITAL REMOTE MODE PROGRAMMING USING IEEE 488.2 (GPIB) INTERFACE

KLP Power Supplies may be programmed over the IEEE 488 standard communication bus
(General Purpose Interface Bus, GPIB) control bus using SCPI (Standard Commands for Pro-
grammable Instruments). SCPI provides a common language conforming to IEEE 488.2 for
instruments used in an automatic test system (see Section 6). Refer to Table 7-1 for GPIB port
input/output signal allocations. All power supply functions available from the front panel can be
programmed via remote commands, as well as some that are not available from the front panel:
Save/Recall (see PAR. 1.2.5), List (see PAR. 1.2.6) and Relay Control (see PARs. B.10 and
B.11
).

7.2

IEEE 488 (GPIB) BUS PROTOCOL

Table 7-2 defines the interface capabilities of the KLP power supply (Talker/Listener) relative to
the IEEE 488 (GPIB) bus (reference document ANSI/IEEE Std 488: IEEE Standard Digital Interface
for Programmable Instrumentation
) communicating with a Host Computer—Controller (Talker/Lis-
tener). Tables 7-3 and 7-4 define the messages sent to the KLP, or received by the KLP, via the
IEEE 488 bus in IEEE 488 command mode and IEEE 488 data mode, respectively. These mes-
sages are enabled during the “handshake” cycle, with the KLP power supply operating as either
a Talker or a Listener.

TABLE 7-1. IEEE 488 PORT CONNECTOR (J4) PIN ASSIGNMENTS

PIN

SIGNAL NAME

FUNCTION

1

D

I

01

I/O Line

2

D

I

02

I/O Line

3

D

I

03

I/O Line

4

D

I

04

I/O Line

5

EOI

End or Identify

6

DAV

Data Valid

7

NRFD

Not Ready for Data

8

NDAC

Not Data Accepted

9

IFC

Interface Clear

10

SRQ

Service Request

11

ATN

Attention

12

SHIELD

Shield

13

D

I

05

I/O Line

14

D

I

06

I/O Line

15

D

I

07

I/O Line

16

D

I

08

I/O Line

17

REN

Remote Enable

18

GND

Ground (signal common)

19

GND

Ground (signal common)

20

GND

Ground (signal common)

21

GND

Ground (signal common)

22

GND

Ground (signal common)

23

GND

Ground (signal common)

24

LOGIC GND

Logic Ground