KEPCO KLP Series Developers Guide, Rev 3 User Manual
Page 132

B-26
KLP 041213
-150,”String data error”
Command Error bit 5 Invalid characters were detected in numeric entry.For example E.1
instead of E+1 or 4d3 instead of 4.3.
-203,”Command protected”
Execution Error bit 4 Password must be CENabled.
-207,”Location is empty”
Execution Error bit 4 Recalled location has no data stored.
-211,”Trigger Ignored”
Execution Error bit 4 Trigger ignored because output is off.
-213,”INIT ignored”
Execution Error bit 4 Request for measurement ignored because another measurement
already in progress.
-221,”Settings conflict”
Execution Error bit 4 E.g. , Invalid password from syst:pass:cen command. or Calibration
state not enabled but CALibrate command received.
-222,“Current, Voltage or Data out of
range”
Execution Error bit 4 Value (current or voltage) exceeds power supply rating or (data)
exceeds acceptable command parameters.
-223,”Data format error”
Execution Error bit 4 Multiple decimal points, Multiple exponents, etc.
-224,“Illegal parameter value”
Execution Error bit 4 For example, OUTP 2 instead of OUTP 1.
-226,“Lists not same length”
Execution Error bit 4 During a LIST command, number of DWEL list entries was not equal to
1 and did not match number of LIST:VOLT or LIST:CURR entries.
-280,“Program Error“
Execution Error bit 4 LIST execution error, e.g., program already running.
-301,”Value bigger than limit”
Device Error bit 3
E.g., requesting a voltage or current that exceeds the limit.
-302, “Mode changed to Voltage”
-302, “Mode changed to Current”
Device Error bit 3
Power supply operating in current mode changed to voltage mode.
Power supply operating in voltage mode changed to current mode.
-303, “Output Lead Fault”
Device Error bit 3
Excessive voltage drop detected between power and sense lead.
-304, “Current Protection Fault”
Device Error bit 3
Current exceeded programmed protection value.
-305, “Voltage Protection Fault”
Device Error bit 3
Voltage exceeded programmed protection value.
-306, “Over Temperature Shutdown”
Device Error bit 3
Internal temperature exceeded thermal protection limit.
-307, “Power Loss Fault”
Device Error bit 3
Source power loss occurred.
-308, “Fan Fault”
Device Error bit 3
Fan fault detected.
-310,”System Failure”
Device Error bit 3
Program checksum incorrect.
-311,”Memory Error”
Device Error bit 3
E.g., power-up NV RAM error, or CALibrate:STORe error.
-313,”Calibration Memory Lost”
Device Error bit 3
No valid calibration found.
-314,”Save/recall memory error”
Device Error bit 3
Using cell other than 1 - 40 for SAV and RCL.
-315,”Configuration Memory Error”
Device Error bit 3
Configuration Memory Error.
-330,”Self Test Failed”
Device Error bit 3
Self test failed.
-340,”Calibration Failure”
Device Error bit 3
Unable to perform auto calibration.
-341,”Non Volatile Mem. CRC
error”
Device Error bit 3
Power supply constants may be corrupted; recalibration may be neces-
sary.
-350,”Queue Overflow”
Device Error bit 3
More than 15 errors are in queue. Error queue was full, error events
have been lost.
-410,”Query interrupted”
Query Error bit 2
New command sent before data from previous query read. Previous
query data lost.
-430,”Query Deadlocked”
Query Error bit 2
Over 255 characters received in single input string.
TABLE B-5. ERROR MESSAGES (CONTINUED)
ERROR MESSAGE
ESR ERROR BIT SET
(SEE PAR. A.5)
EXPLANATION