beautypg.com

Table 5-2. pattern generation example, 8 pattern execution – KEPCO KLP Series Developers Guide, Rev 3 User Manual

Page 78

background image

5-16

KLP-DEV 041213

By using combinations of the four basic waveform types, complex waveforms can be generated,
and repeated using the Pattern Execution window (see PAR. 5.5.2.8) to provide great flexibility
in determining the output.

5.5.2.8

PATTERN EXECUTION

The Pattern Execution window (Figure 5-15) allows the program established by either the pat-
tern generation window or imported file (see PAR. 5.5.2.2) to be executed. If the Loop Direc-
tion
is set to UP, the Loop From window establishes the point in the loop that will start
repeating. For example, if the list is 10 points, and Loop From is set to 3, the first 2 points would
only be executed once, and the points from 3 to 10 would be repeated the number of times
specified in the Loop Count Window. If Loop Count is set to 0 the program will run continuously
until stopped by the user The RUN button starts the program. While the program is running the
Running indicator is on and the RUN button changes to a STOP button used to halt the pro-
gram. When the program is halted, the unit reverts to the settings in effect prior to issuing the
RUN command. If the Loop Direction is set to DOWN, the entire loop will be repeated in the

TABLE 5-2. PATTERN GENERATION EXAMPLE

STEP

PARAMETER

ENTER

RESULT

1

Destination

VOLTAGE

Press GENERATE button after all parameters entered to
add first 50 points to the list:

Waveform

SINE

Frequency (Hz)

2.000

Start Angle

0.000

End Angle

90.000

Amplitude (p-p)

20.000

Waveform Offset

0.000

Current

1.000

Relay

OFF

Points

50

2

Destination

VOLTAGE

Press GENERATE button after all parameters entered to
add second 50 points to list which will produce the following
output:

Waveform

TRIANGLE

Frequency (Hz)

2.000

Start Angle

90.000

End Angle

180.000

Amplitude (p-p)

20.000

Waveform Offset

0.000

Current

1.000

Relay

OFF

Points

50