Table 5-2. pattern generation example, 8 pattern execution – KEPCO KLP Series Developers Guide, Rev 3 User Manual
Page 78

5-16
KLP-DEV 041213
By using combinations of the four basic waveform types, complex waveforms can be generated,
and repeated using the Pattern Execution window (see PAR. 5.5.2.8) to provide great flexibility
in determining the output.
5.5.2.8
PATTERN EXECUTION
The Pattern Execution window (Figure 5-15) allows the program established by either the pat-
tern generation window or imported file (see PAR. 5.5.2.2) to be executed. If the Loop Direc-
tion is set to UP, the Loop From window establishes the point in the loop that will start
repeating. For example, if the list is 10 points, and Loop From is set to 3, the first 2 points would
only be executed once, and the points from 3 to 10 would be repeated the number of times
specified in the Loop Count Window. If Loop Count is set to 0 the program will run continuously
until stopped by the user The RUN button starts the program. While the program is running the
Running indicator is on and the RUN button changes to a STOP button used to halt the pro-
gram. When the program is halted, the unit reverts to the settings in effect prior to issuing the
RUN command. If the Loop Direction is set to DOWN, the entire loop will be repeated in the
TABLE 5-2. PATTERN GENERATION EXAMPLE
STEP
PARAMETER
ENTER
RESULT
1
Destination
VOLTAGE
Press GENERATE button after all parameters entered to
add first 50 points to the list:
Waveform
SINE
Frequency (Hz)
2.000
Start Angle
0.000
End Angle
90.000
Amplitude (p-p)
20.000
Waveform Offset
0.000
Current
1.000
Relay
OFF
Points
50
2
Destination
VOLTAGE
Press GENERATE button after all parameters entered to
add second 50 points to list which will produce the following
output:
Waveform
TRIANGLE
Frequency (Hz)
2.000
Start Angle
90.000
End Angle
180.000
Amplitude (p-p)
20.000
Waveform Offset
0.000
Current
1.000
Relay
OFF
Points
50