beautypg.com

KEPCO KLP Series Developers Guide, Rev 3 User Manual

Page 28

background image

3-6

KLP-DEV 041213

The setting of voltage and current is then very simple.

// set voltage
hr = outputPtr->VoltageLevel(75.0);
if (FAILED(hr))

exit(1);

// set the current limit
hr = outputPtr->CurrentLimit(10);
if (FAILED(hr))

exit(1);

// enable the output
outputPtr->Enabled = true;

Sleep(500);

Note that a measurement requires accessing a function, not a variable.

// measure the voltage
double measVoltage;
measVoltage = measurementPtr->Measure(KepcoDCPwrMeasurementVoltage);

FIGURE 3-1. EXAMPLE OF SETTING THE OUTPUT AND TAKING A MEASUREMENT,

WRITTEN IN C++ (SHEET 1 OF 2)

/*~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
This program demonstrates how to set a voltage and current
measure the output voltage
using the IVI-COM driver.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~*/

#include
#include
#include
#include

#import "IviDriverTypeLib.dll" no_namespace
#import "IviDCPwrTypeLib.dll" no_namespace
#import "KepcDCPwr.dll" no_namespace

int main(int argc, char* argv[])
{
HRESULT hr;

try
{

hr = CoInitialize(NULL);
if (FAILED(hr))

exit(1);

// create a safe pointer for interface access
IKlpPtr driverPtr=NULL;
hr = driverPtr.CreateInstance(__uuidof(KepcoDCPwr));
if (FAILED(hr))

exit(1);